It is a flexible unshielded cable with multi-wire conductors.
This cable was developed as there have been many requests recently where a specifically external cable is needed for moving connections (video equipment in elevators that are mounted in raw mines, specific equipment such as Starlink that needs to be re-mounted many times, and accordingly, repair in the field).
KGPP-VP (100) 4*2*0.48 (U/UTP-cat.5E-SL patch AWG26)
The cable is used in the production of flexible cords (patch cords) for external laying (telephone sewers, mine collectors, walls of buildings). Operation at frequencies up to 100 MHz with rated voltages up to 72 VDC.
The cable complies with the IEC 61156 standard for category 5E.
Technical characteristics of the cable:
Operating temperature range: from -50 0C to +60 0C.
Bending radius: not less than 8 cable diameters
Minimum period of use: 15 years.
Cable design:
1 – Conductive wire
2 – Twisted pair
3 – Waist insulation
4 – Shell
Design dimensions and materials of cable elements
Element | Units of measurement | Value |
Conductive wire | A string of 7 copper wires | |
Diameter (nominal) | mm | 0,489(7х(0,163±0,005)) |
Insulation
Insulation diameter, no less |
Polyethylene | |
mm | 0,72 | |
Transmitting element | Twisted pair | |
Bundle | Four pairs twisted with matched steps in matching color identification | |
Waist insulation | Synthetic tape | |
Shell
Radial thickness, no less Diameter, no more |
Поліетилен | |
mm | 0,5 | |
5,2 | ||
Cable weight (estimated) | kg/km | 21,5 |
Electrical characteristics of the cable
Parameter | Units of measurement | Value |
Electrical capacity, no more | nF/km | 56 |
Electrical resistance of the current-conducting wire, no more | Ohm/km | 145 |
Ohmic asymmetry of wires in a pair, no more | % | 2 |
Electrical resistance of the insulation, no less | MW∙km | 5000 |